The full-automatic headspace sampler can use 10ml and 20ml headspace bottles to meet a large number of analysis requirements. The starting bottle position and the ending bottle position can be set freely to realize special requirements on site. The sample bottle oscillation function accelerates the balance time, improves efficiency, and enhances sensitivity and reproducibility. The 6-bit sample heating position can overlap heating, automatically detect missing sample bottles, and reduce the disorder of sequence analysis.
Full-automatic headspace sampler10ml and 20ml headspace bottles can be used to meet a large number of analysis requirements. The starting bottle position and the ending bottle position can be set freely to realize special needs on site. The sample bottle oscillation function accelerates the balance time, improves efficiency, and enhances sensitivity and reproducibility. The 6-bit sample heating position can overlap heating, automatically detect missing sample bottles, and reduce the disorder of sequence analysis.
Headspace sampler reliable results and reproducibility, valve and loop technology is currently used in high reliability, analysis results with high reproducibility of technology, fixed volume and known volume of samples, accurate temperature control to ensure good reproducibility, to avoid the risk of false results, sample condensation. The sample flow path is all heat preservation and chemically inert treatment, which reduces the analysis residue and keeps the sample intact.
Headspace sampler can be controlled directly through the touch screen, can also be controlled by software on the computer. Powerful, simple and clear operation interface greatly improves work efficiency. Can be operated on the instrument touch screen and computer respectively, the method and sequence can be easily edited and saved, and applied to the instrument, the injection status is displayed in real time, and the temperature condition is visually presented.
The use of a full-automatic headspace sampler can carry out simple and rapid chromatographic analysis of volatile compounds in any sample system, so that analysts can reduce the cumbersome process and time of sample processing. The failure of the headspace sampler is easy to be found. Sometimes the liquid chromatograph system fails and it is impossible to determine whether the sampler is faulty. Manual sampling can be used for several times, or a good automatic sampler can be used instead, if the failure is eliminated, indicates a problem with the autosampler.