Execution requirements for thermal desorber
Release time:
2021-12-13
Source:
Author:
The thermal analyzer is a two-way full-automatic direct sample injection thermal desorption instrument. The gas circuit adopts the combination of electric six-way valve and solenoid valve, which can automatically program the desorption, injection and back-blowing of the adsorption tube. The heating temperature of the adsorption tube and the heating temperature of the pipeline can be set independently. During injection, the synchronous signal is output, and the instrument can start the chromatography and the workstation at the same time.
thermal analyzerIt is a two-way full-automatic direct sample injection thermal desorption instrument. The gas circuit adopts the combination of electric six-way valve and solenoid valve, which can automatically program the desorption, injection and back-blowing of the adsorption tube. The heating temperature of the adsorption tube and the heating temperature of the pipeline can be independently set. During injection, the synchronous signal is output, and the instrument can start the chromatography and the workstation at the same time.
Do you know what the operating requirements of the thermal desorption tower are? Let's take a look.
1) Compatibility requirements. At present, after some workstation hardware is connected to the computer, there will be system crash, workstation crash, system restart, mouse jump and other phenomena. These phenomena of thermal desorption instrument need to be avoided from the source during development.
2) Requirements for measurement range. In the field of preparative chromatograph and ion chromatograph, the measurement range is usually more than 1V, reaching 5V or higher. The thermal desorption instrument requires the hardware to be expandable, and the above requirements can be met with a little modification.
3) sampling frequency and resolution requirements. The development of rapid analysis equipment such as capillary electrophoresis chromatography and ultra-liquid chromatography; the increasing demand for trace analysis; the discussion of "0", "3", "7" and the high reproducibility of retention time on the Internet Continuous fermentation.
4) Requirements for communication interface. In order to keep up with the changes of the host, USB communication is currently regarded as a bright spot by domestic manufacturers, but USB communication itself has the defect that the signal is easily interrupted. It is recommended to provide a serial port option in addition to USB communication.