Indoor environment monitoring (TVOC) dedicated chromatography workstation
The working curve of toluene was automatically applied to calculate the total content of all unknown peaks in the spectrum.
Classification:
Accessories/Consumables
Chromatography workstation
Dedicated Workstation
Hotline:
400-005-7070
Weight
0
Quantity
-
+
Inventory
0
隐藏域元素占位
- Product Description
-
- The working curve of toluene was automatically applied to calculate the total content of all unknown peaks in the spectrum.
- According to the ambient temperature and pressure, the sampling volume is converted to the standard state, and the total content of each component and each component in the unit sampling volume is automatically calculated.
- The peak area of each component in the solvent and the content of each component in the outdoor air sample can be deducted to obtain the final result.
- The calculation method is fully in line with the requirements of national standards, eliminating the trouble of manual secondary calculation and greatly improving work efficiency.
- The analysis report can print the analysis results of outdoor samples and indoor samples at the same time, and can print the working curve graph, working curve equation and correlation coefficient of each component at the same time.
- automatically transfers the calculation results to a user-definedin the Excel report.
- Two channels work independently and can be done with one channelTVOC analysis, another channel to do the analysis of benzene series (can automatically calculate the sum of xylene).
- The software has an audit tracking function. The user records the important operations of each spectrogram and saves it together with the spectrogram. The spectrogram and related contents such as processing methods, quantitative results, remarks, operation records, etc. are all stored in a spectrogram file. The spectrogram file also records the operator's name, injection time, total operation serial number and other information,Ensure the integrity, authenticity and accountability of experimental data. SoftwareAt the same time, an independent system log is set up to record the time of each login software and the name of the operator, the injection time of each needle sample, the total running serial number and the name of the generated spectrogram file, which can completely trace back the detailed process of all experiments,ComplianceGLP specification.The software can also be automatically audited, deleted, replaced or modified.The spectrogram file at the Windows time will be automatically listed.