Beijing Bei Fen Tianpu Instrument Technology Co., Ltd


Beijing Beifen Tianpu Instrument Technology Co., Ltd.

+
  • 50-全.png

Number:

1200124386548011008

TD-50 thermal analyzer


& nbspTD-50 automatic thermal analyzer adopts brand-new graphical design, large-screen industrial-grade touch real color screen control interface, and unique innovative and advanced intelligent design concept. It is the fifth generation of replacement products independently developed by Beijing Beiten Tianpu Instrument Technology Co., Ltd., with high performance and high stability, and is currently the most advanced single-stage thermal analysis product in China.

Classification:

Automatic thermal analyzer

Hotline:

400-005-7070

Weight

0

Quantity
-
+

Inventory

0

隐藏域元素占位

  • Product Description
  • Parameter Description
  • Application areas
  • File Download
  • The TD-50 automatic thermal analyzer adopts a brand-new graphical design, a large-screen industrial-grade touch real color screen control interface, and a unique innovative and advanced intelligent design concept. It is the fifth generation independently developed by Beijing Beipen Tianpu Instrument Technology Co., Ltd. The replacement product has high performance and high stability. It is currently the most advanced single-stage thermal analysis product in China.

     

    Main features of the instrument:

    1. It can be connected with GC/GC-MS of any brand at home and abroad.

    2. Graphically designed touch color screen control interface, Chinese/English display and input, password setting and protection.

    3. Full automatic control, simple operation and convenient use: just put the sample tube into the thermal analyzer, and all operations and controls are automatically completed. The integrated user interface provides real-time system status, including an indication of the progress of each sample, a dynamic picture, at a glance.

    Powerful control software, with extraordinary temperature control accuracy and stability, greatly improving the performance of the instrument.

    5, the use of domestic ultra-leading six-way valve drive technology, high temperature resistance, no dead volume, no adsorption, to ensure excellent reproducibility.

    6. The whole machine adopts modular design, which makes the structure more reasonable and easy to maintain.

    7. The TD-50 can automatically realize the whole process of leak detection, online sampling, dry blowing, analysis, sample injection and cleaning through three operation modes, sampling mode (optional), analysis mode and aging mode. The fully automated design makes complex sample analysis unusually simple and reliable.

    8. The instrument adopts high precision regulator valve, high precision, stable and reliable pressure.

    9, advanced.The sample transmission pipeline and valve body heating control technology completely eliminates the condensation phenomenon in the sample transmission process,

    10、The integrated design of heating valve box and heating gas circuit reduces its adsorption and reduces the problem of low resolution rate caused by dead volume to the greatest extent.
    11The unique patented design of the analytical furnace allows one adsorption tube to analyze while compatible with the aging of two analytical tubes for easy standby at any time.

    12,The seal design of the joints at both ends of the analytical tube is scientific and reasonable, and the assembly operation is convenient.

    13、Fault alarm and self-diagnosis: display the fault condition, user-friendly self-diagnosis and maintenance, and save records

    14, has12Analysis methods for editing, storage and recall at any time, easy to start and analyze quickly. .

    15. For active substance analysis, 0.53mm elastic quartz tube can be selected as sample transfer tube.

    16. Optional electronic airflow control (EPC).

    17. Anti-leakage and over-temperature protection.

    18, the instrument can also synchronously start the chromatography data processing workstation communication interface.

     

    Main technical parameters:

    1. Analytic furnace temperature and control range: room temperature~400℃, adjusting increment 0.1 ℃

    2. Temperature and control range of six-way valve injection system: room temperature~260℃, adjusting increment 0.1 ℃

    3. Temperature and control range of sample transfer tube: room temperature ~ 260 ℃, adjusting increment 0.1 ℃

    4. Temperature control accuracy: ± 0.1 ℃

    5. Repeatability: RSD<1.5%.

    6Timing range:

    7Resolution efficiency: under selected sample components and corresponding operating conditions98%~100% 

    82. Solution tube specification: suitable for outer diameter6mm-7mmVarious standard adsorption tubes. Material can be stainless steel tube, quartz glass tube, hard glass tube

    9. Power: 400W

    10. Power supply: 220VAC 50HZ

  •  

    Performance characteristics:

    One-button operation

    can be used in conjunction with any brand of GC.

    The screen uses a graphical design of the touch screen control interface, Chinese/English display and input.

    There are three operating modes to choose from, namely sampling mode, resolution mode and aging mode.

    10 user-defined analysis methods can be stored.

    The whole and segmented automatic leak detection and fault alarm, diagnostic log.

    The sampling pump can be selected to realize the online sampling task.

    Electronic flow control (EPC) is optional.

    Depending on the detector, a variety of gases can be used as carrier gases.

    triple leakage and triple over-temperature protection.

    There are two sets of automatic and manual purge systems.

    highly consistent system-wide thermostatic technology.

    The transmission tube of the whole machine is passivated.

    The clearer modular structure minimizes adsorption and dead volume.

    The efficient six-way valve assembly optimizes the analysis and injection of samples.

    The communication interface of the chromatographic data processing workstation can be started synchronously.

    Ethernet interface supports LAN, lab network, or fixed IP

    Main technical indicators:

    ▪Analysis of furnace temperature and control range: room temperature -450 ℃.

    ▪Temperature and control range of six-way valve injection system: room temperature -260 ℃.

    ▪Sample transfer tube temperature and control range: room temperature -220 ℃.

    ▪Temperature control increment 1 ℃.

    ▪Temperature control accuracy: ± 0.1 ℃

    ▪Repeatability: RSD<1.5%

    ▪Analytical recovery rate:>98% (depending on component properties and operating conditions)

    ▪Resolution tube specifications: suitable for various standard adsorption tubes with outer diameters of ¢ 6 and 1/4 inch. Material can be stainless steel tube, quartz glass tube, hard glass tube

    ▪Power consumption: 300W

    ▪Overall dimensions: length 45mm × width 32mm × height 40mm

    ▪Weight: 19Kg

  • Main technical indicators:

    ▪Analysis of furnace temperature and control range: room temperature -450 ℃.

    ▪Temperature and control range of six-way valve injection system: room temperature -260 ℃.

    ▪Sample transfer tube temperature and control range: room temperature -220 ℃.

    ▪Temperature control increment 1 ℃.

    ▪Temperature control accuracy: ± 0.1 ℃

    ▪Repeatability: RSD<1.5%

    ▪Analytical recovery rate:>98% (depending on component properties and operating conditions)

    ▪Resolution tube specifications: suitable for various standard adsorption tubes with outer diameters of ¢ 6 and 1/4 inch. Material can be stainless steel tube, quartz glass tube, hard glass tube

    ▪Power consumption: 300W

    ▪Overall dimensions: length 45mm × width 32mm × height 40mm

    ▪Weight: 19Kg

  • Main technical indicators:

    ▪Analysis of furnace temperature and control range: room temperature -450 ℃.

    ▪Temperature and control range of six-way valve injection system: room temperature -260 ℃.

    ▪Sample transfer tube temperature and control range: room temperature -220 ℃.

    ▪Temperature control increment 1 ℃.

    ▪Temperature control accuracy: ± 0.1 ℃

    ▪Repeatability: RSD<1.5%

    ▪Analytical recovery rate:>98% (depending on component properties and operating conditions)

    ▪Resolution tube specifications: suitable for various standard adsorption tubes with outer diameters of ¢ 6 and 1/4 inch. Material can be stainless steel tube, quartz glass tube, hard glass tube

    ▪Power consumption: 300W

    ▪Overall dimensions: length 45mm × width 32mm × height 40mm

    ▪Weight: 19Kg

Related recommendations

Message consultation