Technical parameters:
Temperature control range of headspace furnace: room temperature~260℃
Six-way valve sampling system temperature control range: room temperature~220℃
Sample transfer tube temperature control range: room temperature~220℃
Temperature control accuracy: ±0.1℃
Number of headspace furnace work:1Bit
Number of vials:20Bit
sample bottle specifications:10mlor20ml
Repeatability:<1.5%(200ppmethanol aqueous solution)
Power:500W
Power:AC220V 50Hz
Instrument size:50×32× 60(cm)
Instrument weight: approx.30kg
Instrument features and main functions:
Fully automatic one-button start, unattended
Stable and reliable hardware and software control system
Touch screen control, rich interface information, simple operation
10This method is available for editing, storage and recall at any time, enabling quick start-up and analysis.
Synchronously start the gas chromatograph and chromatographic data processing workstation, or start the device with an external event program.
Achieve multiple repeat injections of the same vial
Sets loop balance time
The combination of six-way valve and quantitative ring reduces the dead volume to the maximum extent and ensures the injection accuracy.
The connection point between the six-way valve and the transmission pipeline is in the heating insulation box, and there is no transmission cold point, which ensures the integrity of the sample.
Gas circuit automatic leak detection, fault alarm
12Month warranty: parts, electronics and software, excluding wearing parts
Optional parts:
Oscillation mode (speed0-300r/min) Shorten balance time, improve sensitivity and repeatability
Electronic pressure/flow (EPC/EFC2) Dual Control
PCEnd software can control the instrument, acquisition status, record log and post-tracking.
Key words:- 全自动顶空进样器
-
Technical parameters:
Temperature control range of headspace furnace: room temperature~260℃
Six-way valve sampling system temperature control range: room temperature~220℃
Sample transfer tube temperature control range: room temperature~220℃
Temperature control accuracy: ±0.1℃
Number of headspace furnace work:1Bit
Number of vials:20Bit
sample bottle specifications:10mlor20ml
Repeatability:<1.5%(200ppmethanol aqueous solution)
-
Optional parts:
Oscillation mode (speed0-300r/min) Shorten balance time, improve sensitivity and repeatability
Electronic pressure/flow (EPC/EFC2) Dual Control
PCEnd software can control the instrument, acquisition status, record log and post-tracking.
-
Optional parts:
Oscillation mode (speed0-300r/min) Shorten balance time, improve sensitivity and repeatability
Electronic pressure/flow (EPC/EFC2) Dual Control
PCEnd software can control the instrument, acquisition status, record log and post-tracking.