Beijing Bei Fen Tianpu Instrument Technology Co., Ltd


Beijing Beifen Tianpu Instrument Technology Co., Ltd.

+
  • 62-全.png

Number:

1200124464675311616

AHS-62 automatic headspace sampler (30 position)


Fully automatic one-button start, unattended Advanced algorithms ensure consistent equilibration time for each sample and maximize chromatograph performance Stable and reliable hardware and software control system Touch screen control, rich interface information, simple operation 10 ways to edit, store and call at any time for quick start and analysis

Classification:

Full-automatic headspace sampler

Hotline:

400-005-7070

Weight

0

Quantity
-
+

Inventory

0

隐藏域元素占位

  • Product Description
  • Parameter Description
  • Application areas
  • File Download
  • Technical parameters:

    Temperature control range of headspace furnace: room temperature~260 

    Six-way valve sampling system temperature control range: room temperature~220

    Sample transfer tube temperature control range: room temperature~220

    Temperature control accuracy:±0.1

    Number of headspace furnace work:6Bit

    Number of vials:30Bit

    sample bottle specifications:10mlor20ml

    Repeatability:<1.5%200ppm ethanol aqueous solution)

    Power:400W

    Power:AC220V 50Hz

    Instrument size:50×45×60 (cm)

    Instrument weight: approx.40kg

     

    Instrument features and main functions:

    Fully automatic one-button start, unattended

    Advanced algorithms ensure consistent equilibration time for each sample and maximize chromatograph performance

    Stable and reliable hardware and software control system

    Touch screen control, rich interface information, simple operation

    10This method is available for editing, storage and recall at any time, enabling quick start-up and analysis.

    Synchronously start the gas chromatograph and chromatographic data processing workstation, or start the device with an external event program.

    Achieve multiple repeat injections of the same vial 

    The combination of six-way valve and quantitative ring reduces the dead volume to the maximum extent and ensures the injection accuracy.

    The connection point between the six-way valve and the transmission pipeline is in the heating insulation box, and there is no transmission cold point, which ensures the integrity of the sample.

    Gas circuit automatic leak detection, fault alarm

    Support overlapping heating mode

    Support time progressive mode

    Support multiple headspace mode

    Sets loop balance time

    12Month warranty: parts, electronics and software, excluding wearing parts

     

     

     

    Optional parts:

    Electronic pressure/flow (EPCEFC2) Dual Control

    PCThe end software can control the instrument, acquisition status, record log and post-tracking: 

Related recommendations