PTC-80 full-automatic solid-liquid integrated purging and collection instrument
Weight
0
Inventory
0
隐藏域元素占位
- Product Description
- Parameter Description
- Application areas
- File Download
-
Technical parameters:
Purge pipe temperatureControl range: Room temperature -100 ℃Temperature control accuracy: ± 1 ℃
Six-way valve injection system temperature and control range: room temperature -220 ℃Temperature control accuracy: ± 1 ℃
Sample transfer tube temperature and control range: room temperature -220 ℃Temperature control accuracy: ± 1 ℃
focusing tube temperatureControl range:-40-450℃Heating rate> 4800 ℃/min
Cold trap temperature control range:-40 ℃-room temperatureUsing electronic refrigeration deviceTemperature control accuracy: ± 1 ℃
Temperature control range of dehydrator: 0-200 ℃
Cleaning distilled water temperature control range: room temperature -90 ℃, temperature control accuracy: ± 1 ℃
Temperature control range of solid sample bottle: room temperature -100 ℃, temperature control accuracy: 1 ℃
Sample bit: 76 bit
Purge flow:10~ 150 ml/min (continuously adjustable)
Time control range: 0.0min ~ 999.9min
Power: 800W
Power supply: 220V 50Hz
Instrument features and main functions:
Fully automatic one-button start,Automatically complete sample injection analysisNo personnel on duty
Purge and trap many types of solid and liquid samples such as drinking water, wastewater and soil
Liquid sample support U-tube ex-situ or in situ purge and trap samples
Solid sample supported heating and continuously adjustable magnetic bead agitation for purge and trap
Automatic leak detection and fault alarm function of purging and collecting instrument
The sampling arm of the injection system moves smoothly and accurately with low noise
Purge capture instrument touch screen control, interface information rich, complete, simple operation
Method parameter setting, real-time display of working status, running time
All temperature control links and devices can be individually controlled temperature
10methods for editing, storing, and calling at any time,Press the run key to automatically complete the sample analysis
Synchronously start GC/GCMS, data processing workstation, can also use external event program to start the device, improve efficiency, reduce sample waste
The trap and purge tube have independent blowback systems to reduce cross-contamination between samples.
The whole process of inert pipeline connection transmission, reduce pollution residue
The connection point between the six-way valve and the transmission pipeline is in the heating insulation box, and there is no transmission cold point, which ensures the integrity of the sample.
The water trap removes water vapor at the purge end, greatly reducing the effect of water vapor on GC and GC/MS
12Month warranty: parts, electronics and software, excluding wearing parts
Main applicable standards
HJ 639-2012Water quality-Determination of volatile organic compounds-Purge and trap/gas chromatography-mass spectrometry
HJ 686-2014Water quality-Determination of volatile organic compounds-Purge and trap/gas chromatography-mass spectrometry
HJ 605-2011Soil and sediment-Determination of volatile organic compounds-Purge and trap/gas chromatography-mass spectrometry
HJ 866-2017Water quality-Determination of turpentine-Purge and trap/gas chromatography-mass spectrometry
HJ 735-2015Soil and sediment-Determination of volatile halogenated hydrocarbons-Purge and trap/gas chromatography-mass spectrometry
HJ 806-2016Water quality-Determination of acrylonitrile and acrolein-Purge and trap gas chromatography
HJ 788-2016Water quality-Determination of acetonitrile-Purge and trap/gas chromatography
HJ 713-2014Solid waste-Determination of volatile halogenated hydrocarbons-Purge and trap/gas chromatography-mass spectrometry